Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Vet Res Commun ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656657

RESUMEN

Mastectomy is a common and painful procedure in dogs. Wound soaker catheters (WSC) are frequently used to reduce postoperative pain, including pain after mastectomy. The objectives of this case series were to describe the use of WSC for owner administration of postoperative local analgesia in dogs with mammary tumors treated surgically, to identify complications associated with WSC and to determine the frequency of bacterial colonization of the catheters. Twelve WSC were placed in 11 dogs during mastectomy surgery, left in place for three days, protected by a dressing and successfully managed by owners at home. No postoperative antibiotics were administered. No complications were identified in any cases. No bacterial growth was identified on bacteriological analysis of the twelve WSC. These results suggest that the use of WSC is a safe alternative for postoperative analgesia administration following mastectomy in dogs. Future studies comparing dogs with or without WSC with a larger number of dogs are needed to further evaluate efficacy and complications.

2.
Animals (Basel) ; 13(15)2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37570284

RESUMEN

Appropriate use of perioperative antimicrobials can significantly reduce the risk of post-operative infections. However, inappropriate antimicrobial use can result in the creation of multidrug-resistant bacteria, increased costs, host flora disruption, side effects and increased risk of hospital-acquired infections. This survey evaluated the current perioperative use of antimicrobials in small animals by Spanish veterinarians using a web-based questionnaire. Responses were represented using descriptive statistics and a statistical analysis of the association between demographic data and perioperative antimicrobial use was performed. Pre-operative antimicrobials were administered in clean surgery by up to 68.3% of participants, 81.0% in clean-contaminated surgery and 71.3% in dirty surgery, while in the post-operative period, antimicrobials were administered by up to 86.3% of participants in clean surgery, 93.2% in clean-contaminated surgery and 87.5% in dirty surgery. Factors considered "very important" for antimicrobial selection were the degree of wound contamination, patient immunosuppression and use of prosthesis. The most frequently used antimicrobial was beta-lactamase-resistant (or potentiated) penicillin. Post-operative antimicrobial use was associated with participants without specific surgical postgraduate training. This study highlights an overuse of antimicrobials in perioperative procedures in small animal surgery in Spain. Therefore, evidence-based guidelines and further education regarding the correct use of antimicrobial prophylaxis are recommended.

3.
Vet Surg ; 52(5): 648-660, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37071824

RESUMEN

OBJECTIVE: To compare pin placement accuracy, intraoperative technique deviations, and duration of pin placement for pins placed by free-hand probing (FHP) or 3D-printed drill guide (3DPG) technique. SAMPLE POPULATION: Four greyhound cadavers. METHODS: Computed tomography (CT) examinations from T6-sacrum were obtained for determination of optimal pin placement and 3DPG creation. Two 3.2/2.4-mm positive profile pins were inserted per vertebra, one left and one right from T7-L7 (FHP [n = 56]; 3DPG [n = 56]) by one surgeon and removed for repeat CT. Duration of pin placement and intraoperative deviations (unanticipated deviations from planned technique) were recorded. Pin tracts were graded by two blinded observers using modified Zdichavsky classification. Descriptive statistics were used. RESULTS: A total of 54/56 pins placed with 3DPGs were assigned grade I (optimal placement) compared with 49/56 pins using the FHP technique. A total of 2/56 pins placed with 3DPGs and 3/56 pins using the FHP technique were assigned grade IIa (partial medial violation). A total of 4/56 pins placed using the FHP technique were assigned grade IIIa (partial lateral violation). No pins were assigned grade IIb (full medial violation). Intraoperative technique deviations occurred with 6/56 pins placed using the FHP technique and no pins with 3DPGs. Overall, pins were placed faster (mean ± SD 2.6 [1.3] vs. 4.5 [1.8] min) with 3DPGs. CONCLUSIONS: Both techniques were accurate for placement of spinal fixation pins. The 3DPG technique may decrease intraoperative deviations and duration of pin placement. CLINICAL RELEVANCE: Both techniques allow accurate pin placement in the canine thoracolumbar spine. The FHP technique requires specific training and has learning curve, whereas 3DPG technique requires specific software and 3D printers.


Asunto(s)
Clavos Ortopédicos , Fijación de Fractura , Perros , Animales , Clavos Ortopédicos/veterinaria , Fijación de Fractura/métodos , Fijación de Fractura/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Impresión Tridimensional
4.
Vet Surg ; 52(6): 853-863, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36811178

RESUMEN

OBJECTIVE: To describe arthroscopic-assisted hip toggle stabilization (AA-HTS) in cats, evaluate its feasibility and associated rate of iatrogenic injury, and assess deviations from planned surgical technique. STUDY DESIGN: Ex vivo study. ANIMALS: Skeletally mature cat cadavers (n = 7). METHODS: Preoperative pelvic computed tomography (CT) was performed for surgical planning and to identify the ideal femoral bone tunnel projection. Ultrasound-guided transection of ligament of head of femur was performed. Following exploratory arthroscopy, AA-HTS was performed using a commercially available aiming device. Surgical time, intraoperative complications, and feasibility of technique were recorded. Iatrogenic injury and technique deviations were assessed by postoperative CT and gross dissection. RESULTS: Diagnostic arthroscopy and AA-HTS were successfully performed in all 14 joints. Median (range) surgical time was 46.5 (29-144) min, including 7 (3-12) min for diagnostic arthroscopy and 40 (26-134) min for AA-HTS. Intraoperative complications occurred in 5 hips, related to bone tunnel creation (4) and toggle dislodgment (1). Toggle passage through the femoral tunnel was the most challenging component of technique, recorded as mildly difficult in 6 joints. No damage to periarticular/intrapelvic structures was identified. Minor articular cartilage damage (<10% total cartilage area) was identified in 10 joints. Thirteen deviations (8 major, 5 minor) in surgical technique from preoperative planning were identified in 7 joints. CONCLUSION: In feline cadavers AA-HTS was feasible but was associated with a high rate of minor cartilage injury, intraoperative complications, and technique deviations. CLINICAL SIGNIFICANCE: Hip toggle stabilization using an arthroscopic-assisted approach may be an effective technique for management of coxofemoral luxation in cats.


Asunto(s)
Enfermedades de los Gatos , Luxación de la Cadera , Gatos/cirugía , Animales , Artroscopía/veterinaria , Artroscopía/métodos , Estudios de Factibilidad , Luxación de la Cadera/cirugía , Luxación de la Cadera/veterinaria , Cadáver , Enfermedad Iatrogénica/veterinaria , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía
5.
Vet Surg ; 50(5): 1042-1053, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33713478

RESUMEN

OBJECTIVE: To report overall rate and type of complications and outcomes of cats with coxofemoral luxation managed with hip toggle stabilization (HTS), to compare rate of postoperative complications and outcomes of cats treated with ultrahigh-molecular-weight-polyethylene (UHMWPE) or nylon, and to identify risk factors for reluxation and non-excellent outcomes. STUDY DESIGN: Multi-institutional retrospective cohort study. SAMPLE POPULATION: Forty-eight client-owned cats. METHODS: Medical records of cats that underwent HTS from 2008-2018 using UHMWPE or nylon were reviewed. Univariable and multivariable logistic regression was performed to assess for factors associated with reluxation and non-excellent outcome. Final outcome was obtained from owner questionnaire. RESULTS: Intraoperative and postoperative complications were recorded in two (4.2%) and 11 (24.4%) cats, respectively. The most common postoperative complication was reluxation (n = 5 [11.1%]). Outcome was classified as excellent in 81.1% and good in 16.2% of cats after a median of 445.5 days (range, 53-3720). No difference in rate of complications or outcomes was identified between UHMWPE and nylon. Performance of additional orthopedic procedures, occurrence of intraoperative complications, and non-performance of capsulorrhaphy were associated with reluxation. Performance of additional non-hip procedures (orthopedic/nonorthopedic) was associated with non-excellent outcome. CONCLUSION: Hip toggle stabilization was associated with a low rate of intraoperative complications and reluxation and excellent long-term outcomes in most cats. No difference in rate of postoperative complications or outcomes of cats treated using UHMWPE or nylon was identified. Cats that underwent additional orthopedic procedures had greater risk of reluxation. CLINICAL SIGNIFICANCE: Hip toggle stabilization is an effective technique for management of coxofemoral luxation in cats. Comparable results are expected using UHMWPE or nylon.


Asunto(s)
Enfermedades de los Gatos/cirugía , Luxación de la Cadera/veterinaria , Nylons , Procedimientos Ortopédicos/veterinaria , Polietilenos , Complicaciones Posoperatorias/veterinaria , Animales , Gatos , Femenino , Luxación de la Cadera/cirugía , Masculino , Procedimientos Ortopédicos/instrumentación , Procedimientos Ortopédicos/métodos , Complicaciones Posoperatorias/epidemiología , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
6.
Vet Surg ; 49(8): 1527-1535, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33015879

RESUMEN

OBJECTIVE: To determine the effect of stifle flexion on the proximity of the cranial tibial artery to the proximal tibia in canine stifles with an intact or transected cranial cruciate ligament (CCL). STUDY DESIGN: Ex vivo randomized blinded computed tomographic angiographic study. SAMPLE POPULATION: Fifteen pelvic limbs from eight greyhound cadavers. METHODS: The femoral artery and vein were cannulated and injected with 10 mL of iohexol. Each limb was placed in lateral recumbency on an acrylic sheet with predrawn femoral and tibial lines representing angles of stifle extension. Computed tomography was performed before (limbs 1-15) and after (limbs 10-15) CCL transection. The shortest distance between the cranial tibial artery and proximal tibia (dCrTA-PT) was measured at a distance of one patellar length from medial intercondylar tubercle. RESULTS: Median dCrTA-PT in intact specimens at 70°, 90°, 110°, and 135° was 2.04, 2.05, 2.28, and 2.51 mm, respectively (P = .008). Pairwise comparisons identified a difference between 70° and 135° (P = .007). Mean dCrTA-PT in transected specimens at 70°, 90°, 110°, and 135° was 2.60, 2.57, 2.90, and 2.79 mm, respectively (P = .208). Median overall dCrTA-PT was 2.24 mm in intact specimens (limbs 1-15, all four angles of extension combined) and 2.76 mm in transected specimens (limbs 10-15, all angles combined; P = .01). CONCLUSION: Flexion of the stifle resulted in a negligible decrease in dCrTA-PT in intact specimens but had no effect in CCL transected stifles. CLINICAL SIGNIFICANCE: The angle of stifle extension does not appear to have any clinically significant effect on the proximity of cranial tibial artery to the proximal tibia.


Asunto(s)
Ligamento Cruzado Anterior/fisiología , Rango del Movimiento Articular , Rodilla de Cuadrúpedos/fisiología , Tibia/fisiología , Arterias Tibiales/fisiología , Animales , Cadáver , Perros , Femenino , Masculino
7.
Vet Rec Open ; 6(1): e000233, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31673370

RESUMEN

OBJECTIVES: To determine (1) the incidence of surgical site infection (SSI) in patients undergoing soft tissue surgery at a veterinary teaching hospital and to study (2) and describe the main risk factors associated with SSI and (3) assess the economic impact of SSI. DESIGN: Prospective cohort study. SETTING: Veterinary teaching hospital. PARTICIPANTS: 184 dogs undergoing soft tissue surgery during a 12-month period (October 2013 to September 2014). PRIMARY OUTCOME MEASURE: Surgical site infection. RESULTS: Out of the 184 patients analysed, SSI was diagnosed in 16 (8.7 per cent) patients, 13 (81.3 per cent) were classified as superficial incisional infection, 2 (12.5 per cent) as deep incisional infection and 1 (6.3 per cent) as organ/space infection. The administration of steroidal anti-inflammatory drugs (P=0.028), preoperative hyperglycaemia (P=0.015), surgical times longer than 60 minutes (P=0.013), urinary catheterisation (P=0.037) and wrong use of the Elizabethan collar (P=0.025) were identified as risk factors. Total costs increased 74.4 per cent, with an increase in postsurgical costs of 142.2 per cent. CONCLUSIONS: The incidence of SSI was higher than the incidence reported in other published studies, although they were within expected ranges when a surveillance system was implemented. This incidence correlated with an increase in costs. Additionally new important risk factors for its development were detected.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...